The professional choice for smart and efficient heating
Elevate your pool experience with the SensaPool PiX Series 17kW Inverter Ultra Quiet Pool Heat Pump, where luxury meets cutting-edge innovation. Designed for discerning homeowners across Australia and New Zealand, this premium heat pump combines advanced inverter technology with a Mitsubishi DC compressor for unmatched efficiency and whisper-quiet performance.
Featuring a side-discharge design and reduced clearance requirements, it’s the ultimate space-saving solution that blends effortlessly into any poolside setting. With WiFi-enabled touch controls, eco-friendly R32 refrigerant, and a durable titanium heat exchanger, the PiX 17kW delivers precise heating and cooling for year-round comfort.

Backed by an industry-leading warranty—25 years on the heat exchanger, 10 years on the compressor, 5 years on parts, and 2 years on-site service—this heat pump offers peace of mind alongside exceptional quality.
Benefits:
- Cost Efficiency: Advanced inverter technology minimizes energy use, lowering bills while maintaining ideal pool temperatures.
- All-Season Versatility: Reverse cycle heating and cooling ensures a perfect swim, no matter the weather.
- Tranquil Operation: Ultra-quiet design enhances relaxation with minimal noise disruption.
- Remote Convenience: WiFi connectivity and intuitive touch controls let you manage your pool from anywhere.
- Sustainable Performance: Eco-friendly R32 refrigerant reduces environmental impact without sacrificing power.
- Long-Term Reliability: Comprehensive warranties (25-year heat exchanger, 10-year compressor) guarantee lasting value.
- Space-Saving Style: Side discharge and compact design fit seamlessly into any pool area.

Eco Friendly R32 Gas

Mitsubishi DC Compressor

Reverse Cycle, Heating & Cooling

On the titanium heat exchanger
Key Features:
- Latest Inverter Technology for precise, energy-efficient operation
- Ultra Quiet Operation with advanced sound insulation and Mitsubishi DC Compressor
- Reverse Cycle Functionality for heating and cooling
- Reduced Clearances for easy installation in tight spaces
- Improved Touch Control with standard WiFi connectivity
- Titanium Heat Exchanger for corrosion resistance and longevity
- Eco-Friendly R32 Refrigerant for greener performance
- Side Discharge Air Outlet for optimal airflow and space efficiency
Ventilation Requirements:
All SensaPool inverter heat pumps must to be installed in an outdoor/well ventilated area.
- The diagram displays the minimum outdoor ventilation area required for optimum performance.
- Locate the heat pump in an easily accessible position to ensure easy access for operation and service.
- Ensure condensation water discharged from the bottom of the heat pump has a course to freely drain away.
Model Number |
HPPiX11 |
HPPiX14 |
HPPiX17 |
HPPiX22 |
HPPiX27 |
HPPiX32s |
HPPiX40s |
Distance A (mm) |
500 |
500 |
500 |
500 |
500 |
500 |
500 |
Distance B (mm) |
500 |
500 |
500 |
500 |
500 |
500 |
500 |
Distance C (mm) |
150 |
150 |
200 |
250 |
300 |
300 |
300 |
Distance D (mm) |
1500 |
1500 |
1500 |
1500 |
1500 |
1500 |
1500 |
Optional Accessories:
- DT-H5RO-I Heat Pump Interface / Controller
Heat Demand. As most pools are filtered for 8 hours a day, extra run times are often required to maintain the water at the desired temperature. The heat pump is equipped with a "Demand Heat" function that will assist in maintaining the temperature of the pool by communicating to the H5R0-I. The controller will over-ride the filter pump when heat is called for by the heat pump which monitors the temperature within its defined run times. By this mean, the user is sure the water is always ready to bathe, day or night.
Warranty:
- 25 years: Anti-corrosion warranty on the titanium heat exchanger coils
- 5 years: Compressors
- 2 years: Parts
- 2 years: On-site Labour
PiX Series Specifications:
Model |
HPPiX11 |
HPPiX14 |
HPPiX17 |
HPPiX22 |
HPPiX27 |
HPPiX32s |
HPPiX40s |
Performance Condition: Air 27C/ Water 27C/ Humidity 80% |
Heating capacity (Kw) |
11.5 |
14.0 |
17.0 |
22.5 |
26.5 |
31.5 |
40.5 |
COP Range |
15.0-7.3 |
15.0-7.4 |
15.0-7.1 |
15.5-7.4 |
15.2-7.3 |
15.8-7.2 |
16.0-7.0 |
Average COP at 50% Speed |
11.4 |
11.0 |
11.1 |
11.8 |
11.5 |
11.6 |
11.5 |
Performance Condition: Air 15C/ Water 26C/ Humidity 70% |
Heating capacity (Kw) |
17.7 |
9.2 |
11.5 |
15.0 |
18.0 |
22.1 |
29.0 |
COP Range |
7.5-5.0 |
7.6-5.1 |
7.8-5.0 |
8.2-5.1 |
7.9-5.2 |
8.0-5.0 |
8.3-5.1 |
Average COP at 50% Speed |
6.7 |
6.5 |
6.5 |
7.0 |
6.8 |
7.0 |
7.0 |
Performance Condition: Air 35C/ Water 28C/ Humidity 80% |
Cooling Capacity (Kw) |
4.6 |
5.6 |
6.5 |
8.1 |
10.2 |
12.3 |
15.0 |
Technical Specifications |
Reverse Cycle |
Standard |
Operating Air Temperature (C) |
-15C ~ 43C |
Heating Temperature Range (C) |
18C ~ 40C |
Cooling Temperature Range (C) |
12C ~ 30C |
WiFi |
Standard |
Heat Exchanger |
Twisted Titanium |
Power Supply |
230V 1 Ph |
400V 3 Ph |
Electrical Connection |
10A Plug |
15A Plug |
15A Plug |
Hard Wired |
Hard Wired |
Hard Wired |
Hard Wired |
Rated Input Power (Kw) |
0.24-1.79 |
0.29-2.16 |
0.36-2.67 |
0.45-3.33 |
0.54-4.00 |
0.60-4.42 |
0.78-5.80 |
Rated Input Current (A) |
1.04-7.78 |
1.26-9.39 |
1.57-11.63 |
1.96-14.48 |
2.35-17.39 |
0.86-6.41 |
1.13-8.41 |
Maximum Input Current (A) |
9 |
11 |
13 |
16 |
18 |
8 |
13 |
Sound Level at 1m dB (A) |
36.3-44.5 |
36.5-45.9 |
39.3-46.7 |
39.5-49.8 |
39.8-50.2 |
40.5-50.9 |
40.6-51.3 |
Sound Level at 10m dB (A) |
16.3-24.5 |
16.5-25.9 |
19.3-26.7 |
19.5-29.8 |
19.8-30.2 |
20.5-30.9 |
20.6-31.3 |
Advised Water Flow (L/Min) |
34-67 |
50-67 |
67-100 |
100-150 |
134-167 |
167-200 |
200-300 |
Water Connection (mm) |
40mm |
Net Weight (kg) |
66 |
73 |
75 |
91 |
114 |
148 |
164 |
Net Dimension L x W x H (mm) |
750 x 504 x 656 |
750 x 504 x 656 |
840 x 504 x 656 |
980 x 504 x 756 |
1135 x 514 x 756 |
1153 x 528 x 957 |
1285 x 530 x 957 |
Basic "extended season" heater sizing guide
The below table is a guide for extending your swimming season (Sept-April). Many factors contribute to selecting the correct heater size, we always recommend that a sizing evaluation be completed before purchasing any heater.
These values are calculated using the average temperature, humidity and wind speed in the location listed.
|
20,000L |
40,000L |
60,000L |
80,000L |
Brisbane |
9-13kW |
9-13kW |
13-17kW |
20-21kW |
Sydney |
9-13kW |
13kW |
20-21kW |
24-28kW |
Melbourne |
13kW |
20-21kW |
28kW |
35kW |
Canberra |
13kW |
20-21kW |
28kW |
35kW |
Hobart |
13kW |
20-21kW |
28kW |
35kW |
Adelaide |
13kW |
16-17kW |
24-28kW |
35kW |
Perth |
9-13kW |
16-17kW |
21-24kW |
28kW |
Please Note: These recommendations are a guide only. The above table lists sizes for an extended season (Sept-April) with a swimming temperature of 28 degrees Celsius. Calculations are based on average pool dimensions for an in-ground pool using a cover with a run time of 10 hours a day with an average wind exposure and standard shading. Temperature loss and heat up time will vary according to the month of the year, quality of cover if installed, soil condition, shade, wind and weather conditions.