AstralPool Viron Connect 10 – Setup Guide, Manual & Video Tutorials

This is your complete guide for setting up and operating the AstralPool Viron Connect 10 pool and spa automation system. Below you’ll find step-by-step video tutorials covering everything from basic system configuration to advanced features like solar heating, valve programming, and lighting control.

To unlock full remote control capabilities, use the ConnectMyPool App in combination with the Internet Gateway Module. This powerful setup allows you to monitor and manage your pool from anywhere. Setup instructions, firmware updates, and troubleshooting resources are included below.


1. Basic System Setup: Chlorinator, Pump & Heater

This video guides you through the initial configuration of your Viron Connect 10 controller, allowing you to set up your connected equipment such as:

  • Filter Pump (incl. variable-speed models)
  • Viron eQuilibrium Chlorinator (controlled via data cable)
  • AstralPool Genus Gas Heater

You’ll use the Setup Wizard to define:

  • Number of lighting zones and control channels (up to 8)
  • Equipment type assigned to each channel
  • Whether a Genus heater is installed
  • Pump type (variable or single speed)
  • Timer use and AI Mode for chlorinator integration
  • Whether valves, solar heating, or dual pool/spa modes are required

In this example, a Viron P320 variable-speed pump is connected to a Viron eQuilibrium chlorinator, and managed entirely through Connect 10 using AI Mode. The Genus gas heater is also included, while solar, lighting, and spa mode are excluded.

This basic setup forms the foundation for advanced configurations such as:

  • Heat demand scheduling
  • Valve and lighting control
  • Remote access via the ConnectMyPool app

► Video: AstralPool Viron Connect – Basic Setup


2. Enabling Heat Pump Communication (Local Mode Setup)

Before your Viron Connect 10 can properly control a heat pump, it must be configured to use Local Mode. By default, the system is set to System Mode to communicate with a Genus gas heater. If you're using an electric or inverter heat pump along with a temperature sensor, this jumper setting must be changed.

This video walks you through the physical configuration:

  • Power down the controller at the main isolator or circuit breaker
  • Open the controller housing and locate the internal jumper
  • Move the bridging pin from the right-hand side (System Mode) to the left-hand side (Local Mode)
  • Reconnect and secure the panel
  • Plug in your water temperature sensor

This step enables the touchscreen controller to monitor water temperature and send start/stop signals to the heat pump. Without this setting, the system cannot manage heating cycles based on demand.

► Video: AstralPool Viron Connect – Communication with Heat Pump System / Local Configuration


3. Heat Pump Setup: Part 1 – Timed Heating Control

This video covers how to link your heat pump with the Viron Connect system using a timer-based configuration. You’ll learn how to:

  • Assign dedicated equipment channels for heat pump control
  • Link a single-speed filtration pump to activate the heater’s pressure switch
  • Set spa and pool temperature targets
  • Add the heater to your filtration schedule
  • Enable cool-down sequences to protect the heater after shutdown

Watch this first if your heat pump is controlled via filtration timers rather than demand sensing.

► Video: AstralPool Viron Connect – Heat Pump Configuration Part 1: Timers


4. Heat Pump Setup: Part 2 – Heat Demand Mode

Learn how to automate pool heating with Heat Demand on the Viron Connect 10. This video walks you through configuring the system so it samples your pool temperature hourly and runs the heater only when needed – optimising energy use.

In this step, you’ll:

  • Enable heat demand mode via the Setup Wizard
  • Assign a timer period (e.g., 5am–9pm)
  • Configure temperature regulation from the touchscreen
  • Learn how the system synchronises heater and pump cycles

Use this setup if you want automatic heating based on temperature, not just timers.

► Video: AstralPool Viron Connect – Heat Pump Configuration Part 2: Heat Demand


5. Programming Solar with Filter Pump

This tutorial shows how to configure solar heating in the Viron Connect 10 system when using the same pump for both filtration and solar operation.

The setup uses the inbuilt solar automation features of Viron Connect. By enabling temperature sensing and collector flushing, your system will automatically detect when solar heating conditions are ideal and activate the solar valve and filter pump accordingly.

Once complete, the solar system will:

  • Monitor both roof and water temperatures
  • Activate heating when the roof is sufficiently warmer
  • Flush solar collectors daily
  • Override the filtration timer if solar heating is required

This setup helps maximise your solar gain without needing an additional circulation pump and ensures efficient use of your existing equipment.

► Video: AstralPool Viron Connect – Programming Solar with Filter Pump


6. Programming Solar with Separate Pump

This tutorial explains how to configure solar heating in your Viron Connect 10 system when using a separate pump dedicated to solar circulation – ideal when your solar system runs independently of the filtration cycle.

By selecting the "Connect Inbuilt" solar mode and assigning the solar pump to an unused channel (e.g., Channel 2), the system will:

  • Automatically monitor roof and pool temperatures
  • Activate the dedicated solar pump only when needed
  • Flush the solar collectors daily to maintain hygiene and efficiency
  • Operate independently from the filter pump’s timer

This setup ensures your solar system operates optimally without interfering with normal filtration, providing more efficient and targeted solar heating.

► Video: AstralPool Viron Connect – Programming Solar with Separate Pump


7. Programming a Solar Valve (Inbuilt Control)

This guide explains how to configure a solar heating valve using the Viron Connect 10’s inbuilt solar automation features.

The system allows your solar heating to operate automatically based on temperature differences between the roof collectors and pool water. You can also program collector flushing and filter pump support.

Once enabled, the system checks solar conditions continuously. If sunlight is strong enough and the pool is below the target temperature, the solar valve will open and start circulation, even if the filtration timer is off.

► Video: AstralPool Viron Connect – Programming Solar Valve


8. Programming an Auxiliary Valve

Learn how to configure an auxiliary valve using the Viron Connect 10 controller. Auxiliary valves are used for features such as:

  • Waterfalls or water features
  • Spa blowers
  • Bubbler zones
  • Deck jets or fountains

In this example, the installer adds a new valve for a water feature, names it, and enables it for timer scheduling and favourites.

Once programmed, this valve can be toggled manually or included in automated schedules and favourite modes–allowing seamless control of your extra pool features through the touchscreen or ConnectMyPool app.

► Video: AstralPool Viron Connect – Programming a Valve


9. Programming Lighting

This tutorial walks you through setting up lighting zones in your Viron Connect 10 controller. Perfect for pool and spa areas with single-colour or transformer-powered lights, it allows you to independently control and name each lighting area.

Key functions covered:

  • Activating the Setup Wizard to enable lighting zones
  • Naming two independent zones (e.g. "Pool" and "Spa")
  • Disabling multi-colour lighting options if not using Delta Colour Control
  • Assigning lighting to available relay channels (e.g. Channel 3 for Pool, Channel 4 for Spa)

Controlling lights easily from the touchscreen interface or remotely via ConnectMyPool app

This setup gives you full flexibility over pool and spa ambience, with the ability to automate, schedule, or instantly activate your lights from anywhere.

► Video: AstralPool Viron Connect – Programming Lighting


10. Programming Favourites

The Favourites feature on your Viron Connect 10 controller lets you combine multiple pool or spa actions into a single touch command. Whether it’s turning on pumps, lights, or valves, you can save and instantly recall your preferred settings.

In this video, you'll learn how to:

  • Navigate to the Configure Favourites menu
  • Name your Favourite (e.g. "Spa Time")
  • Add equipment like filter pumps, lighting zones, or water feature valves
  • Set speeds or modes (e.g. high-speed pump, coloured lighting)
  • Enable your Favourite so it appears on the home screen

Create your own personalised modes – like "BBQ Night," "Spa Time," or "Poolside Waterfall" – and activate them instantly with a single touch.

► Video: AstralPool Viron Connect – Programming Favourites


11. ConnectMyPool App & Internet Gateway Setup

Control your pool from anywhere in the world with the ConnectMyPool App and the Internet Gateway Module.

What You Can Do:

  • View real-time pool temperature
  • Change the heater set-point
  • Turn on/off pumps, valves, blowers, and lighting
  • Change lighting colours (if multicolour lights are installed)
  • Activate your favourite modes – like "Spa Time", "BBQ Night", or "Waterfall"

Available for both iOS and Android:

Note: The app requires the Internet Gateway Module to be installed and connected via Wi-Fi or Ethernet.

Installation, Setup & Troubleshooting

Quick-Start Resources:

12. Firmware Updates

Keep your system running smoothly with the latest firmware for your Internet Gateway and Colour Touchscreen. Select the correct version based on your hardware below.

Device Firmware Version Compatible With Download
Internet Gateway v4.1 Gateway v4.0 only Download
v3.2 Gateway v3.0 – v3.1 Download
v2.4 Gateway v1.0 – v2.3 Download
Colour Touchscreen v3.9 Touchscreen v3.0 and above Download